John Deere 4045 and 6068 OEM Diesel Engines — Checking Engine Mounts

Lubrication & Maintenance/500 Hour/12 Month Servicing Fire Extinguisher A fire extinguisher (A) is available from your authorized servicing dealer or engine distributor. Read and follow the instructions which are packaged with it. The extinguisher should be inspected at least every 500 hours of engine operation or every 6 months. Once extinguisher is operated, no matter how long, it must be recharged. Keep record of inspections on the tag which comes with the extinguisher instruction booklet. RW4918 –UN–15DEC88 Fire Extinguisher A—Fire Extinguisher OURGP11,000015F –19–28JAN04–1/1 Checking Engine Mounts Engine mounting is the responsibility of the vehicle or generator manufacturer.

Follow manufacturer’s guidelines for mounting specifications. IMPORTANT: Use only Grade SAE 8 or higher grade of hardware for engine mounting. RG9905 –UN–06JAN99 1. Check the engine mounting brackets (A), vibration isolators, and mounting bolts on support frame and engine block for tightness. Tighten as necessary. Engine Mounting 2. Inspect overall condition of vibration isolators, if equipped. Replace isolators, as necessary, if rubber has deteriorated or mounts have collapsed. A—Mounting Bracket OURGP11,0000110 –19–16OCT03–1/1 30-1 021604 PN=138