Kubota — Kubota Engine Manual (EN)

15 PERIODIC SERVICE 4. If the oil level is too low, remove the oil filler plug, and add new oil to the prescribed level. 5. After adding oil, wait more than 5 minutes and check the oil level again. It takes some time for the oil to drain down to the oil pan. B Change of engine oil ENGLISH To avoid personal injury: A Be sure to stop the engine before draining engine oil. A When draining engine oil, place some container underneath the engine and dispose it according to local regulations. A Do not drain oil after running the engine. Allow engine to cool down sufficiently. Engine oil quantity Oil quantities shown are for standard oil pans. 1.

Change oil after the initial 50 hours of operation and every 200 hours thereafter. 2. Remove the drain plug at the bottom of the engine, and drain all the old oil. Drain oil will drain easier when the oil is warm. A Engine oil should be MIL-L-2104C or have properties of API classification CD grades or higher. Change the type of engine oil according to the ambient temperature. A When using oil of different brands from the previous one, be sure to drain all the previous oil before adding the new engine oil. (1) Oil drain plug 3. Add new engine oil up to the upper limit of the oil level gauge.

CAUTION Models Quantity D905-E, D1005-E, D1105- E, D1105-TE 5.1 L (1.35 U.S.gals.) V1205-E, V1305-E, V1505-E 6.0 L (1.59 U.S.gals.) V1205-TE, V1505-TE 6.7 L (1.77 U.S.gals.) above 25°C (77°F) SAE30 or SAE10W-30 SAE15W-40 -10°C to 25°C (14 to 77°F) SAE10W-30 or SAE15W-40 below -10°C (14°F) SAE10W-30