BODY (UPPERSTRUCTURE) / Pump Device MAINTENANCE STANDARD Pump Device 1. Plunger assembly: Shoe thickness Standard Allowable Limit A 8 mm (0.31 in) 7.7 mm (0.30 in) 2. Plunger: Clearance between shoe and plunger 3. Rotor: Clearance between plunger outer diameter and cylinder block bore A W176-02-04-020 B W176-02-04-020 4. Clearance between housing inner diameter and servo piston outer diameter C a W176-02-04-021 b D W176-02-04-022 W2-6-30 Standard Allowable Limit B 0.15 mm (0.01 in) 0.4 mm (0.02 in) Standard Allowable Limit (C-a) 0.03 mm (0.001 in) 0.07 mm (0.003 in) Standard Allowable Limit (D-b) 0.02 mm (0.0008 in) 0.04 mm (0.002 in)