GENERAL / Tightening PIPING JOINT IMPORTANT: The torques given in the chart below are for general use only. Do not use these torques if a different torque is given for a specific application. Union Joint Metal sealing surfaces (4) and (5) of adapter (1) and hose (2) fit together to seal pressure oil. Union joints are used to join small-diameter lines. IMPORTANT: 1. Do not over-tighten nut (3). Excessive force will be applied to metal sealing surfaces (4) and (5), possibly cracking adapter (1). Be sure to tighten nut (3) to specifications. 2. Scratches or other damage to sealing surfaces (4) or (5) will cause oil leakage at the joint.
Take care not to damage them when connecting/disconnecting. 1 3 5 2 4 M202-07-051 Joint Body 37 ° 30 ° Female Union Joint Male Union Joint W105-01-01-017 NOTE: Tightening torque of 37 ° male coupling without union is similar to tightening torque of 37 ° female. W1-2-5 Description Wrench Size mm Wrench Size mm Tightening Torque Union Nut Joint Body N⋅m (kgf⋅m, lbf⋅ft) 37°female 17 19 22 27 32 36 14 17 19 22 27 32 24.5 (2.5, 18) 29.5 (3.0, 21.5) 39 (4.0, 28.5) 93 (9.5, 69) 137 (14.0, 101) 175 (18.0, 129)