Full-load maximum speed operation Partial load spring Governor spring Damper spring YZ a it (jfP"2 Flyweight hhh eS eG Pod spmpmyes tielelele > Tension lever ~ PS Governor sleeve Ms (fixed) “at noel 53: Negative torque control stroke a I M2 (pivot) = iZ Control sleeve Fig. 41 Operation of governor equipped with negative torque control device: full-load maximum speed operation When the control lever is moved until it con- tacts the maximum speed stopper, engine Speed is increased until the full-load maximum speed is reached. At this time the yoke is pulled to the extreme left (refer to Fig.
41), the partial load spring is fully compressed, the governor spring Is compressed and the tension lever is pulled to the left until it contacts the 34 Stopper pin Ms (i.e. where the full-load injection quantity is obtained). | With an increase in speed the flyweights’ centrifugal force increases and the governor sleeves acts to move the tension lever against the force of the governor spring to move the control sleeve and maintain full-load maximum Speed operation.