Komatsu — FINAL DRIVE CASE OIL LEVEL - CHECK/ADD

MAINTENANCE PROCEDURE MAINTENANCE Final Drive Case Oil Level - Check/Add 0. The oil is at high temperature immediately after the machine has been operated. Wait for the oil to cool down before starting the operation. If there is still pressure remaining inside the case, the oil or plug may fly out. Loosen the plug slowly to release the pressure. Prepare a container to catch drained oil. Prepare a hexagon wrench. 1. Turn the sprocket so that plug (P) is at the bottom. 2. Set the container to catch oil under plug (P). 3. Remove plug (G) with a hexagonal wrench. Oil level should be near the bottom of the plug hole (G). 4.

If the oil is insufficient, remove plug (F) with a hexagonal wrench, then add oil through plug (F), until oil flows out of level plug hole (G). 5. After checking the oil level, install plugs (F) and (G). 4-52 WARNING