OPERATIONAL PERFORMANCE TEST / Standard ZX200-3 CLASS OPERATIONAL PERFORMANCE STANDARD TABLE The standard Performance values are listed in the table below. Refer to the Group T4-3 to T4-5 for performance test procedures. Values indicated in parentheses are reference values. The following switch positions shall be selected and the hydraulic oil temperature shall be maintained as indicated below as the preconditions of performance tests unless otherwise instructed in each performance test procedure: Engine Control Dial : Fast Idle Power Mode Switch : P Mode Auto-Idle Switch: OFF Work Mode: Digging Mode Hydraulic Oil Temperature :
50 ± 5 ° C (122 ± 41 ° F) T4-2-1 PERFORMANCE TEST DESIGNATION ZX200-3 class (Performance Standard) Remarks Reference Page ENGINE SPEED min-1 T4-3-1 Slow Idle Speed 800±50 Lever in neutral, Value indicated on Dr. ZX Fast Idle Speed (wirh ECO deactivated) 1800±50 ↑ Fast Idle Speed (Heater control: OFF) 1700±50 Lever in neutral, Pilot shut-off lever: UNLOCK position, Value indicated on Dr. ZX Fast Idle Speed (Heater control: ON) 2000±50 Pilot shut-off lever: LOCK position, Coolant temperature: 5 °C or lower, Value indicated on Dr. ZX Fast Idle Speed (Relief operation) 1800±50 Boom raise relief operation, Value indicated on Dr.
ZX Fast Idle Speed (E mode) 1650±50 Lever in neutral, Value indicated on Dr. ZX Fast Idle Speed (HP mode) 2000±50 Relief operation of boom rasie and arm roll-in, Value indicated on Dr. ZX. Auto-Idle Speed 1200±50 Value indicated on Dr. ZX. Warming-Up Speed 1400±100 ↑ ENGINE COMPRESSION PRESSURE MPa (kgf/cm2, psi) 3.04±0.2 (31±2, 442±29) Engine speed: 200min-1 T4-3-3 VALVE CLEARANCE (IN, EX) 0.4 With the engine cold T4-3-4 LUBRICANT CONSUMPTION (Rated output) mL/h 30 or less Hour meter: 2000 hours or less T4-3-7