hitachi — ZX240-3 CLASS DR. ZX MONITOR INDICATING VALUES

OPERATIONAL PERFORMANCE TEST / Standard T4-2-49 Item Reference Value Measured Value Remarks First Second Third Average BOOM RAISE PILOT ∗ CONTROL PRESSURE (MPa) 4.03 When relieving boom raise ARM ROLL-IN PILOT ∗ CONTROL PRESSURE (MPa) 4.01 When relieving arm roll-in SWING PILOT CONTROL ∗ PRESSURE (MPa) 4.11 When relieving swing TRAVEL PILOT CONTROL ∗ PRESSURE (MPa) 4.13 FRONT ATTACHMENT ∗ CONTROL PRESSURE (MPa) 3.99 Operate either of boom, arm, bucket or swing DIGGING REGENERATIVE PROPORTIONAL VALVE OUTPUT (MPa) 3.19 When relieving arm roll-in PUMP TORQUE PROPOR- TIONAL VALVE OUTPUT (MPa) 0.45 Engine fast idle + when relieving arm roll-in PUMP 1 LOAD RATE 68 When relieving arm roll-in PUMP 2 LOAD RATE 68 When relieving arm roll-in ARM REGENERATIVE PRO- PORTIONAL VALVE OUTPUT* (MPa) 2.25 Arm leveling POWER DIGGING CONTROL PRESSURE* (MPa) During operation 2.99 When relieving boom raise 2.99 TRAVEL MOTOR CONTROL PRESSURE* (MPa) 2.99 Travel mode switch:

Fast, When travel- ing PUMP TORQUE PROPOR- TIONAL VALVE OUTPUT FB (mA) 518 When relieving arm roll-in DIGGING REGENERATIVE PROPORTIONAL VALVE OUTPUT FB (mA) 507 When relieving arm roll-in ARM REGENERATIVE PRO- PORTIONAL VALVE OUTPUT FB (mA) 445 Arm leveling POWER DIGGIN CONTROL PRESSURE FB (mA) 500 TRAVEL MODE CONTROL PRESSURE FB (mA) 492 Travel mode switch: Fast, When travel- ing