Kubota — Kubota RTV-500 Operators Manual (EN)

PERIODIC SERVICE 54 B Checking Battery Condition To avoid the possibility of battery explosion: For the refillable type battery, follow the instructions below. A Do not use or charge the refillable type battery if the fluid level is below the LOWER (lower limit level) mark. Otherwise, the battery component parts may prematurely deteriorate, which may shorten the battery's service life or cause an explosion. Check the fluid level regularly and add distilled water as required so that the fluid level is between the UPPER and LOWER levels. (1) Fuel line (2) Hose clamp (3) Three way connector To avoid personal injury: A Never remove the vent caps while the engine is running.

A Keep electrolyte away from eyes, hands and clothes. If you are spattered with it, wash it away completely with water immediately and get medical attention. A Wear eye protection and rubber gloves when working around the battery. The factory-installed battery is non-refillable type. If the battery is weak, charge the battery or replace it with new one. C Battery Charging To avoid personal injury: A When the battery is being activated, hydrogen and oxygen gases in the battery are extremely explosive. Keep open sparks and flames away from the battery at all times, especially when charging the battery. A When disconnecting the cable from the battery, start with the negative terminal first.

When connecting the cable to the battery, start with the positive terminal first. A Never check battery charge by placing a metal object across the posts. Use a voltmeter or hydrometer.