10 Fieldwork settings 10.4 Separation 67086 10.4 Separation 82550 10.4.1 Adjusting the separation performance monitor sensors The cleaning and separation performance monitor allows the operator to make full use of the capacity of the machine. A gauge allows the operator to determine how fast the machine can be driven without the reasonable grain loss limit being exceeded. 2 2 Grains lost over the back of the combine with the straw fall onto the sensors (2). The pulses generated are vis- ualised by meter lights on a display. 4 12 The sensors (2) react with different sensitivities to dif- ferent grain sizes and must therefore be calibrated to the respective grain size, using switch (4).
19647 The gauge sensitivity setting is carried out during field- work. See Adjusting the separation performance monitor display. Adjust the sensitivity of the sensors to the different grain sizes on switch (4). 1 The sensors react more / less sensitively, depending on the pre-set grain size. 2 4 3 13 19650 180 00 0293 210 2 - BA DOMINATOR 150/140/130 - 12/09 Sensitivity of sensors Position Grain sizes 1 for lightweight grains 2 for medium-weight grains 3 for heavy grains