TM2361 (24JUN08) 9005-10-16 450DLC Excavator Operation and Tests 062608 PN=232 Operational Checkout Procedure Travel Alarm Cancel YES: Go to next check. Switch Circuit Check NO: Check travel alarm 5 A fuse (F5) (Marked OPT. 1). See Fuse Test (Group 9015-20.) and see Fuse and Relay Specifications. (Group 9015-10.) TX1005669 –UN–29MAR06 NO: Check wiring. See Cab Harness (W1) Wiring Diagram (Group 9005 9015-10.) and see 10 System Functional 16 Schematic. (Group 9015-10.) TX1000414 –UN–22NOV05 1—Travel Alarm Cancel Switch CAUTION: Machine will move during this check. Make sure area is clear and large enough to operate the machine. NOTE: Travel alarm must operate for this check.
Place pilot shutoff lever (1) to UNLOCKED (forward) position. Push travel pedals or levers and allow travel alarm to operate for a minimum of 12 seconds. LISTEN: Does travel alarm sound? While continuing travel, push travel alarm cancel switch (1). LISTEN: Does travel alarm stop sounding? – – –1/1 Operational Checkout Procedure Travel Alarm Cancel Switch Circuit Check TX1005669 –UN–29MAR06 TX1000414 –UN–22NOV05 1—Travel Alarm Cancel Switch CAUTION: Machine will move during this check. Make sure area is clear and large enough to operate the machine. NOTE: Travel alarm must operate for this check. Place pilot shutoff lever (1) to UNLOCKED (forward) position.
Push travel pedals or levers and allow travel alarm to operate for a minimum of 12 seconds. LISTEN: Does travel alarm sound? While continuing travel, push travel alarm cancel switch (1). LISTEN: Does travel alarm stop sounding? YES: Go to next check. NO: Check travel alarm 5 A fuse (F5) (Marked OPT. 1). See Fuse Test (Group 9015-20.) and see Fuse and Relay Specifications. (Group 9015-10.) NO: Check wiring. See Cab Harness (W1) Wiring Diagram (Group 9015-10.) and see System Functional Schematic. (Group 9015-10.) – – –1/1 9005 10 16