John Deere 450DLC — Monitor Circuit Theory of Operation

Sub-System Diagnostics Engine Speed Dial (R15)— Engine speed dial (R15) has a 5-volt reference voltage supplied by the MCF (terminal D1) and a ground reference shared with the MCF (terminal D6) and the monitor controller (terminal C10). When the engine speed dial is rotated, a corresponding signal is sent to the monitor controller (terminal C4) and the MCF (terminal C1). For additional information on engine speed control, see Main Controller (MCF) Circuit Theory of Operation (Group 9015-15.) and see Engine Speed Control System Operation. (Group 9010-05.) CS33148,00008E9 –19–21APR06–6/6 9015 15 13 TM2361 (24JUN08) 9015-15-13 450DLC Excavator Operation and Tests 062608 PN=457