TM2361 (24JUN08) 9015-20-104 450DLC Excavator Operation and Tests 062608 PN=594 References Diode Check YES: If multimeter beeps in both checks, diode has failed in a shorted mode. Replace the diode. NO: If multimeter does not beep in either check, diode has failed in an open mode. Replace the diode. NO: If multimeter beeps in one check and not the other, diode is OK. T164619B –UN–27JAN03 Remove diode from connector. Test diode using diode test function of multimeter. LISTEN: Does the multimeter beep? Reverse multimeter probes. LISTEN: Does the multimeter beep? 9015 20 ,104 – – –1/1 References Diode Check T164619B –UN–27JAN03 Remove diode from connector.
Test diode using diode test function of multimeter. LISTEN: Does the multimeter beep? Reverse multimeter probes. LISTEN: Does the multimeter beep? YES: If multimeter beeps in both checks, diode has failed in a shorted mode. Replace the diode. NO: If multimeter does not beep in either check, diode has failed in an open mode. Replace the diode. NO: If multimeter beeps in one check and not the other, diode is OK. – – –1/1 9015 20 ,104 Travel Alarm Check Disconnect travel alarm harness connector. Connect multimeter to travel alarm connector pin B and A B machine ground. D C Turn key switch to ON position. LOOK: Is battery voltage measured?
T158291 –UN–08AUG02 Connect multimeter to travel alarm connector pin D and machine ground. LOOK: Is continuity measured? Connect multimeter to travel alarm connector pin A and machine ground. LOOK: Is continuity measured when the travel alarm cancel switch is pressed? YES: Harness is OK. Check travel alarm F5 5A fuse. See Fuse and Relay Specifications. (Group 9015-10.) Travel alarm has failed. Replace the travel alarm. See Travel Alarm Remove and Install. (Group 9015-20.) See Machine Harness (W2) Wiring Diagram. (Group 9015-10.) NO: Check the travel alarm cancel switch harness. Check travel alarm cancel switch. See Cab Harness (W1) Wiring Diagram. (Group 9015-10.) – – –1/1