TM2361 (24JUN08) 9025-05-30 450DLC Excavator Operation and Tests 062608 PN=668 Theory of Operation Pump 1 and 2, Fan Drive Pump, and Gearbox Operation 18 Y12 Y13 17 15 29 26 16 –UN–13APR06 28 27 TX1005680 TX1005680 Hydraulic Pump Locations 15—Pump 1 18—Pump 2 Regulator 28—Fan Drive Pump Y13—Pump 2 Control Solenoid 16—Pump 2 26—Charge Pump 29—Fan Drive Pump Regulator Valve 17—Pump 1 Regulator 27—Pilot Pump Y12—Pump 1 Control Solenoid Valve 9025 05 30 Pump 1 (15), pump 2 (16), charge pump (26), pilot Pumps 1 and 2 are variable displacement, piston type pump (27), and fan drive pump (28) are driven by the pumps; these parallel-arranged pumps supply engine via the engine flywheel-to-pump 2 coupling.
high-pressure oil to the machine’s working circuits. Pump 2 is driven at a 1:1 ratio with the engine and The pilot pump is a gear type pump, which supplies carries the drive gear of the pump drive gearbox. pilot oil to the machine’s control circuits. Pump 1 is driven by the pump 2 drive gear at a 1:32/31 ratio. The charge pump and the pilot pump, The fan drive pump is a variable displacement, piston driven off the end of the pump 1 drive shaft, are also type pump, which supplies pressure oil to the fan driven at a 1:32/31 ratio. The fan drive pump, driven motor of the machine’s cooling system. by an idler gear driven off the pump 2 drive gear, is at a 1:1 ratio.
Pump 1 is controlled by the pump 1 regulator (17), pump 2 is controlled by the pump 2 regulator (18), and The charge pump is a centrifugal type pump, which the fan drive pump is controlled by the fan drive pump supplies positive oil pressure to the input ports of regulator (29). pump 1, pump 2, and the pilot pump to prevent pump cavitation. Continued on next page LD30992,0000257 –19–11APR06–1/3