TM2361 (24JUN08) 9025-05-35 450DLC Excavator Operation and Tests 062608 PN=673 Theory of Operation 15—Pump 1 23—Check Valve 180—Supply Oil 202—Large Chamber 19—Servo Piston 24—Check Valve 182—Pilot Oil 203—Small Chamber 20—Load Sleeve 25—Pilot Piston 184—Return Oil Y12—Pump 1 Control Solenoid 21—Load Spool 27—Pilot Pump 200—Spring Valve 22—Feedback Link 83—To Right Control Valve 201—Pivot Pin Operation of pump 1 regulator and pump 2 regulator is valve (24) if the supply oil pressure becomes lower the same. Pump 1 regulator is discussed throughout. than the pilot oil pressure.
The pump regulators are located at the top of each Regulator Operation at Minimum Flow Rate—With pump and are responsible for the control of the pump pump 1 control solenoid valve open to the tank, the delivery flow rate. The pump control solenoid valve load spool is shifted to the left by the spring. With the (Y12) regulates the pilot control pressure according to spool in this position, supply oil is routed to the large signals received from the main controller (MCF). As chamber (202) of the servo piston. With supply oil at pilot control pressure increases, the pump delivery flow both ends of the servo piston, the servo piston will rate increases.
For more information on the MCF and move to the right, due to the difference in surface the pump control circuit, see Main Controller (MCF) areas on either end. Circuit Theory of Operation. (Group 9015-15.) When the servo piston moves to the right, the Supply oil (180) is routed through check valve (23) to feedback link (22) will rotate counterclockwise, moving load spool (21) and to the small chamber (203) of the the load sleeve (20) to the left. The servo piston will servo piston (19). continue to move to the right until the oil passages on the load sleeve and load spool are completely closed.
Pilot oil (182) from the pump control solenoid valve With the servo piston in this position, the pump swash acts on the pilot piston (25), moving the load spool plate is moved to minimum displacement; thus the back and forth against the spring (200). Pilot oil can pump will deliver minimum flow rate. also be combined with the supply oil through check Continued on next page LD30992,0000258 –19–11APR06–2/4 9025 05 35