Theory of Operation During counterweight removal operation, when the MCF (26) receives an electrical signal from the counterweight pressure sensor, the MCF sends an electrical signal to energize the power dig solenoid valve SG (27). The pilot oil (21) pressure signal from the power dig solenoid valve SG pushes the piston in the main relief valve and power dig valve down, increasing the pressure setting. The main hydraulic system can now operate at a higher operating pressure. The MCF receives signals from pump 1 and pump 2 regulator pressure sensors. The MCF then sends signals to pump 1 and pump 2 control solenoid valves reducing the pump’s flow rates.
Continued on next page LD30992,000025C –19–13APR06–5/6 9025 05 70 TM2361 (24JUN08) 9025-05-70 450DLC Excavator Operation and Tests 062608 PN=708