John Deere 450DLC — Boom Flow Rate Circuit Operation

Theory of Operation Energized— When energized, the magnetic force shifts the spool left against the spring. Pilot oil (24) flows past the spool flange and out the port as a reduced pilot oil to the boom flow rate control valve—switch valve (20). Because the flange on the right is larger than the flange on the left, the spool is pushed to the right against the magnetic force as the electrical signal to the solenoid increases. When the reduced pilot oil pressure becomes equal to or greater than the magnetic force (23), the spool is pushed to the right closing the passage. The reduced pilot oil to the boom flow rate control valve—switch valve is trapped.

The spool is moving constantly to maintain the reduced pilot oil pressure in response to the electrical signal to the solenoid coil. LD30992,0000263 –19–26APR06–7/7 9025 05 92 TM2361 (24JUN08) 9025-05-92 450DLC Excavator Operation and Tests 062608 PN=730