TM2361 (24JUN08) 9025-25-13 450DLC Excavator Operation and Tests 062608 PN=873 Tests NOTE: Spool actuating pressure can be checked for each function by installing a tee and gauge in pilot line and then actuating that function. Spool actuating pressure for boom up, arm in, left and right swing, and all travel functions can also be measured with the monitor. 2. Heat hydraulic oil to specification. See Hydraulic Oil Warm-Up Procedure. (Group 9025-25.) 3. Run machine at specifications. Specification Hydraulic Oil—Temperature........................................................ 45—55°C 110—130°F Engine—Speed.....................................................
Slow Idle and Fast Idle Work Mode Switch—Position...................................................... Dig Mode Power Mode Switch—Position.....................................P (Standard) Mode Auto Idle Switch—Position.................................................................... Off Travel Speed Switch—Position.................................. Fast Speed (Rabbit) 4. Actuate the function control lever to full stroke at slow idle. 5. Record pressure. 6. Compare pressure to specifications. Specification Minimum Valve Spool Actuating— Pressure......................................................................................
3.33 MPa 3334 kPa 33.3 bar 483 psi If valve spool actuating pressure is not to specification check pilot system pressure. See Pilot Pressure Regulating Valve Test and Adjustment. (Group 9025-25.) If pilot system pressure is to specification then check pressure at the solenoid valve manifold, pilot control shutoff valve, pilot controllers, and pilot signal manifold. MS12501,0000096 –19–05JUN06–3/3 9025 25 13