TM2361 (24JUN08) 9025-25-57 450DLC Excavator Operation and Tests 062608 PN=917 Tests 2. See Personal Digital Assistant (PDA) Connection To Excavator Using Dr. ZX Application for instruction. (Group 9015-20.) Select the following items from the Monitor Display: • Pump 1 Delivery Pressure • Pump 2 Delivery Pressure • Hydraulic Oil Temperature • Actual Engine Speed 3. See Monitor Service Menu Operation for instruction to actuate the service menu on monitor in cab. (Group 9015-16.) Select the following items from Monitoring list:
• Pump 1 Delivery Pressure • Pump 2 Delivery Pressure • Hydraulic Oil Temperature • Actual Engine Speed Install 4200465 adapter into test port (1 or 2) for right or left travel circuit. Connect a 70 000 kPa (700 bar) (10,000 psi) gauge or the JT02156A Digital Pressure/Temperature Analyzer and JT02160 Transducer. 2. Turn second adjusting plug of main relief and power digging valve in 1/2 turn to increase pressure setting. See Main Relief and Power Digging Valve Test and Adjustment for adjustment procedure. (Group 9025-25.) 3. Warm hydraulic oil to specification. See Hydraulic Oil Warm-Up Procedure. (Group 9025-25.) Continued on next page TX04577,00000F0 –19–05JUN06–2/4 9025 25 57