John Deere 450DLC — Fan Drive Pump Flow Test

TM2361 (24JUN08) 9025-25-83 450DLC Excavator Operation and Tests 062608 PN=943 Tests SPECIFICATIONS Fan Drive Pump Flow Rate— 48.4 L/min at 23.3 MPa and 1750 Minimum Allowable rpm 48.4 L/min at 23 305 kPa and 1750 rpm 48.4 L/min at 233.1 bar and 1750 rpm 12.8 gpm at 3380 psi and 1750 rpm Fan Drive Pump Flow Rate— 42.8 L/min at 26.3 MPa and 1750 Minimum Allowable rpm 42.8 L/min at 26 270 kPa and 1750 rpm 42.8 L/min at 262.7 bar and 1750 rpm 11.3 gpm at 3810 psi and 1750 rpm SERVICE EQUIPMENT AND TOOLS Flowmeter, 380 L/min (100 gpm) JT03452 Split Flange Connector Plate Kit -12 Hose with -12 Split Flange Connector, Code 62 The purpose of test is to check the condition of fan drive pump. 1.

Release pressure from hydraulic oil tank by pushing pressure release button on top of hydraulic oil tank. 2. Connect a vacuum pump to hydraulic oil tank to minimize oil loss. Continued on next page OUT3035,000000D –19–05JUN06–2/6 9025 25 83 SPECIFICATIONS Fan Drive Pump Flow Rate— Minimum Allowable 48.4 L/min at 23.3 MPa and 1750 rpm 48.4 L/min at 23 305 kPa and 1750 rpm 48.4 L/min at 233.1 bar and 1750 rpm 12.8 gpm at 3380 psi and 1750 rpm Fan Drive Pump Flow Rate— Minimum Allowable 42.8 L/min at 26.3 MPa and 1750 rpm 42.8 L/min at 26 270 kPa and 1750 rpm 42.8 L/min at 262.7 bar and 1750 rpm 11.3 gpm at 3810 psi and 1750 rpm