TM2361 (24JUN08) 9031-15-5 450DLC Excavator Operation and Tests 062608 PN=957 Diagnostic Information Diagnose Heating System Malfunctions NOTE: Diagnostic charts are arranged from most probable and simplest to verify, to least likely more difficult to verify. NOTE: Prior to diagnosis and component tests Perform Air Conditioner and Heater Operational Checks. (Group 9031-25.) These conditions may affect diagnostic and test results. Symptom Problem Solution Heater System Does Not Operate Air conditioner and heater 5 amp Replace fuse. See Fuse and Relay fuse (F17) Specifications. (Group 9015-10.) Air conditioner and heater 20 amp Replace fuse. See Fuse and Relay fuse (F3) Specifications.
(Group 9015-10.) Fan motor malfunction or operating Check fan motor resistor. See Air too slowly Conditioner Harness (W6) Wiring Diagram. (Group 9015-10.) Check fan motor for obstructions. See Heater and Air Conditioner Component Location. (Group 9031-15.) Check fan motor. See Air Conditioner Harness (W6) Wiring Diagram. (Group 9015-10.) Heater and air conditioner controller Check air conditioner diagnostic malfunction trouble codes. See Air Conditioner Diagnostic Trouble Code Check. (Group 9031-15.) Heater Does Not Warm Interior of Fresh air filter restricted Clean or replace filter. See Clean Cab Cab Fresh Air and Recirculating Air Filter.
(Operator’s Manual.) Recirculating air filter restricted Clean or replace filter. See Clean Cab Fresh Air and Recirculating Air Filter. (Operator’s Manual.) Continued on next page LD30992,00004BC –19–23MAR06–1/2 9031 15 5