hitachi — REMOVE AND INSTALL PILOT VALVE

UPPERSTRUCTURE / Pilot Valve 6. Remove clip bands (13) (2 used). Disconnect the connector of harness (14). 7. Loosen lock nut (12). Remove the lever (11) assembly from pilot valve (15). 12 11 13 : 19 mm, 32 mm 8. Remove bolts (17) (3 used). Remove the bracket (5) assembly from stand (16). Lay down the bracket (5) assembly. 14 : 17 mm 9. Remove bolt (19). Remove cover (18) from bracket (5). W1JB-02-07-005 15 : 10 mm 10. Remove hoses (20) (6 used) from pilot valve (15). Attach an identification tag onto the removed hoses for reassembling. Cap the open ends. W1JB-02-07-008 : 19 mm W1JB-02-07-010 15 W1JB-02-07-006 20 W2-7-9 17 16 5 18 19 5