Komatsu — TRANSPORTATION

24. SERVICE PROCEDURE 24.9 EVERY 2000 HOURS SERVICE Maintenance for every 100, 250, 500 and 1000 hours should be carried out at the same time. 24.9.1 CHECK OIL LEVEL IN PTO GEAR CASE, ADD OIL WARNING Immediately after operations, the oil is at a high temperature. Wait for the temperature to go down before starting this opera- tion 1. Swing the upper structure so that the PTO gear case is midway be- tween the left and right tracks. Stop the engine and set the safety lock lever to the LOCK positon. 2. Remove the cover under the right side of the machine. 3. Remove plug and check that the oil level is close to the bottom edge of the plug hole.

If the oil level is low, remove plug , and add oil through the hole of plug until it reaches the bottom of the hole of plug . NOTICE For details of the oil to use, see "20. USE OF FUEL, COOLANT AND LUBRICANTS ACCORDING TO AMBIENT TEMPERATURE". 4. Install plug and plug . 5. Install the cover. PC130/150LGP-6K ENG 3-63