Komatsu — 15.3 AFTER STORAGE

OPERATION 15. LONG TERM STORAGE 15.1 BEFORE STORAGE Prepare the machine for long term storage as follows. Wash and dry every part and move the machine into a dry building. If the machine must be left outdoors, park on well drained concrete and cover with canvas, etc. Completely fill the fuel tank, lubricate, and change the oil before storage. Apply a thin coat of grease to the metal surface of the hydraulic piston rods. Disconnect the negative terminal of the batteries and cover it, or remove it from the machine and store it separately.

If the ambient temperature is expected to drop below 0 (32 Apply the safety locks to the bucket control lever, lift arm control lever, and directional lever, then apply the parking brake. 15.2 DURING STORAGE WARNING Provide necessary ventilation if the machine is operated indoors to prevent gas poisoning. Operate the engine and move the machine for a short distance once a month so that a new film of oil will be coated over movable parts and component surfaces. At the same time, also charge the batteries. Before operating the work equipment, wipe grease from the hydraulic piston rod. 15.3 AFTER STORAGE NOTE:

Special procedures are necessary if the machine is stored without the monthly rust prevention operation. Consult your distributor for service. Carry out the following procedures when taking the machine out of storage. Wipe grease from the hydraulic cylinder rods Add oil and grease at all lubrication points. 2-78 WA320-3MC