TYPES OF DATA STORED Cycle Data One cycle is considered to be from the point where a load is dumped to the point where the next load is dumped. Data between these two points is recorded in memory. Examples of the data are shown below. The maximum number of cycles that can be stored in memory is 2900 cycles. M20007.1 03/02 Payload Meter II M20-11 ITEM UNIT RANGE REMARKS Engine Operation Number Number 1 - 65535 Advances by one each time the engine is started. Month Month 1 - 12 Day Day 1 - 31 Time Hour Hour 24 Hour Clock These values are stored when the load is dumped.
Time Minute Minute 1 - 59 Payload Metric tons Short tons 0 - 6553.5 Travel Time When Empty Minute 0 - 6553.5 Travel Distance When Empty Miles/Km 0 - 25.5 Maximum Travel Speed When Empty Mph/Kmh 0 - 99 Average Travel Speed When Empty Mph/Kmh 0 - 99 Time Stopped When Empty Minute 0 - 6553.5 Time Stopped During Loading Minute 0 - 6553.5 Travel Time When Loaded Minute 0 - 6553.5 Travel Distance When Loaded Miles/Km 0 - 25.5 Maximum Travel Speed When Loaded Mph/Kmh 0 - 99 Average Travel Speed When Loaded Mph/Kmh 0 - 99 Time Stopped When Loaded Minute 0 - 6553.5 Dumping Time Minute 0 - 6553.5 Speed Limit Mph/Kmh 0 - 99 Warnings For Each Cycle The fault codes that occur during each cycle