All data is comma separated and can be imported into most popular spreadsheets and data analysis programs. A typical file looks like this: In the sample data shown, the column marked "Type" refers to the type of data being transmitted; “R” is used for Real-Time, “F” is used for Final Load and “S” is used for Swing Load. For the swing load data line the format is Time, S, Swing Load, Predicted Load, FL, FR, RL, RR. For a final load transmission the format is Time, F, Final Load, FL, FR, RL, RR. Connections to Payload Meter II™ Two harnesses are required to connect a PC to the Payload Meter II™. EF9159 - Connects to the back of the Payload Meter II™ to a panel mount connector.
EF9160 - Connects from the panel mount connector to the PC. The connectors and pins typically used for the payload meter connection are : The Payload Meter requires 5 wire RS232 communications. Payload Meter communications connections are : 1 - RTS 2 - Signal Ground 3 - RxD 4 - TxD 5 - CTS M20-60 Payload Meter II™ Troubleshooting M20007.2 3/02 Description Part Number Terminal 7827101440 Connector 7845253670