30. MACHINES READY FOR ATTACHMENT CONNECTING HYDRAULIC CIRCUIT When connecting the attachment, connect the hydraulic circuit as follows. 1. Remove blind plug 1 at the tip of the stop valve piping. (Left and right, 2 places) Be careful not to lose or damage the removed parts. 2. Connect attachment piping 2 provided by the attachment maker to the part from which the plug was removed. AM092060 When it is shipped from the plant, tube 3 is fitted with an Okada compatible part. In other cases, a Nippon Pneumatic compatible part is also used, but when adding an accumulator, the action to take differs according to the attachment maker, so please contact your Komatsu distributor.
AM092070 PATH OF OIL FLOW The direction of operation of the pedal and the path of the oil flow is as shown in the diagram below. AM092080 5-12