Toyota — Toyota Forklift Manual (EN)

10-24 REAR tilt operation When the tilt lever is pushed to the REAR side, solenoid b2 is energized and the solenoid proportional valve moves to the right. Then the pressure oil controlled by the pressure reducing valve flows to chamber (u) on the left side, and the tilt spool moves to the right side. The volume of oil that flows to chamber (u) is proportional to the distance the lever is operated. Pressure oil flowing from chamber (a) in the inlet section pushes down the load check and shifts the tilt lock check valve, then flows from port C3 to the tilt cylinder rod side. The select valve does not operate at this time, so the select valve becomes simply a check valve.

The pressure differential between chamber (a) and chamber 7 is kept constant by the pressure compensation mechanism and the load sensing mechanism, so the volume of pressure oil supplied to port C3 is determined by the opening aperture of part O irrespective of the load. (a) Load check O Port C3 Port C2 (u) Solenoid b2 7 Tilt spool Solenoid proportional valve