Toyota — Toyota Forklift Manual (EN)

10-27 PUMP MOTOR General 1. The pump motor like the drive motor uses AC induction motor, ideal for the electric forklift design, featuring higher performance even with the compact sizing combined with the maintenance free advantage. Terminal Rotor Field winding 2. Making use of the advantages of the AC induction motor, the motor output has been upgraded with the result that either of the performance, with loaded or with unloaded has been improved. 3. Since the motor does not have brushes, it has become mainte- nance-free.

Speed sensor bearing Thermo sensor Field core Specifications Models Nominal voltage (V) Rated output (kW) Type Body size (mm) Weight (kg) STD 7FBMF16, 18 72/80 12.0/13.5 Three phase AC φ240 × 324 57 7FBMF20, 25, 30, 35 72/80 16.9/18.6 Three phase AC φ240 × 339 60 7FBMF40, 45, 50 72/80 22.8/25.4 Three phase AC φ260 × 427 97