OPERATION 16.3.2 PRECAUTION FOR CHARGING THE BATTERY CHARGING THE BATTERY WHEN MOUNTED ON THE MACHINE Before charging the battery, disconnect the negative (-) battery cable from the battery. This action prevents voltage spikes from damaging the alternator. While charging the battery, remove all battery vents for satisfactory ventilation. To avoid gas explosions, do not bring fire or sparks near the battery. If the electrolyte temperature exceeds 113 charging the battery temporarily. Turn off the charger as soon as the battery is charged. Over charging the battery may cause the following:
1) Overheating the battery 2) Decreasing the quantity of electrolyte 3) Damaging the electrode plate Do not mix the cables (positive (+) to negative (-) ), or the alternator could be damaged. When performing any service to the battery besides checking the electrolyte level or measuring the specific gravity, disconnect the cables from the battery. REMARKS The batteries are on both sides at the rear of the machine. The battery used for the ground is on the left side of the machine. WA450-3MC 2-90