Transmission - CEC Plus II Shift System Section 120-0070 ECU Operating Power Circuit is completed to ground through line 306. Solenoid in Relay 2 closes Switch allowing current (12 volts) to flow through Fuse 6, Line 87, Switch and Lines 202A or 223A to the ECU. Circuit is completed to ground through Lines 208 or 209 and Line 306. Refer to Fig. 6. When the engine is started, current (24 volts) flows through Line 330 and Fuse 7 to Relay 2, energizing solenoid. SM - 1971 W/B(330) W FUSE 7 RELAY 2 B(306) 202 208 209 W(87) FUSE 6 223 ECU B(306) 24V 12V GRD VANNER Fig.

6 - ECU Operating Power Neutral Start Circuit to ground when selector is in Neutral through Line 210, ECU, Lines 208 or 209 and Line 306. Solenoid in Relay 6 closes Switch, allowing current (24 volts) to flow through Line 308, Switch and Line 45 to start solenoid. Refer to SECTION 190-0000, CIRCUIT DIAGRAMS for continuation of starter circuitry. Refer to Fig. 7. The Neutral Start circuit prevents the engine from being started unless the shift selector is in Neutral position. When ignition keyswitch is turned to position '1', current (24 volts) flows through Line 341 and Fuse 4 to Relay 6, energizing solenoid.

Current continues through Line 231 to shift selector, and goes VANNER SM - 1972 GRD 12V 24V BATTERIES + B(306) + - - B(306) SHIFT SELECTOR 210 G/R (231) 208 W/R W/R R/P(341) IGN. SW. FUSE 4 RELAY 6 ECU 209 SOLENOID TERMINAL TO CAB WIRING TO START SOLENOID R(308) U(45) Fig. 7 - Neutral Start Circuit 8 SM 1575 Rev 2 11-00