Transmission - CEC Plus II Shift System Section 120-0070 Reverse Alarm Refer to Fig. 10. When the shift selector is placed in Reverse, ECU closes circuit allowing current (24 volts) to flow through Line 308 and Fuse 1 to Relay 5, energizing solenoid. Current flows through Line 214 to ECU and back to ground through Lines 208 or 209 and Line 306. Solenoid closes Switch, allowing current to flow through Line 308, Switch and Line 75 to reverse alarm. Refer to SECTION 190-0000, CIRCUIT DIAGRAMS for continuation of Reverse Alarm circuitry.

R(308) RELAY 5 SM - 1975 R(308) FUSE 1 R(308) U/W(75) TO REVERSE RELAY ECU 209 G(214) 208 BATTERY DISCONNECT RELAY R B(306) B(306) + + - - 24V 12V GRD BATTERIES VANNER Fig. 10 - Reverse Alarm Reverse Hoist Pressure Switch Refer to Fig. 11. The Reverse Hoist Pressure switch is a safety feature to prevent the vehicle from backing up while the body is being raised. Current from the ECU flows through line 305, microswitch and line 309. If pressure switch is opened by the body control valve being moved to the 'Raise' position, current is interrupted and ECU will shift transmission to Neutral.

To obtain Reverse again, switch must be opened and shift selector must first be placed in Neutral or a forward range. This interlock will not prohibit shifts to a forward range while body is being raised. SM - 1976 SHIFT SELECTOR B(309) W(305) ECU Fig. 11 - Reverse Hoist Pressure Switch Parking Brake Interlock prevents a shift out of Neutral. This interlock will not inhibit shifting if the parking brake is applied while the transmission is operating in reverse or any forward range. Refer to Fig. 12. The Parking Brake Interlock prevents a shift out of Neutral when the parking brake is applied. When the parking brake is applied, switch opens, breaking the circuit to ground.

The ECU then 10 SM 1575 Rev 2 11-00