Terex TR60 — Sm1564 (EN)

Transmission - CEC Plus II Shift System 22 SM 1575 Rev 2 11-00 Section 120-0070 ELECTRICAL TROUBLESHOOTING - No Codes CONDITION REASON REMEDY No Check Trans light when ignition keyswitch is turned to position '1' Faulty light bulb Replace light bulb Faulty Relay 4 Replace Relay 4 Incorrect power to Relay 4 Check circuit from batteries to Relay 4 Faulty wiring to ECU Check J1A harness wiring, interface in control box and wiring from circuit breakers and ignition keyswitch to ECU Faulty ECU Replace ECU Check Trans light will not go out when engine is started Faulty Relay 4. Note 2. Replace Relay 4 Faulty wiring in cab. Note 2.

Check J1A harness and interface in control box Light wired incorrectly . Note 2. Check wiring Oil temperature too low. Note 1. Run engine until oil warms above -23° C (-10° F). Refer to Codes 24 and 33 troubleshooting procedures. Faulty ECU. Notes 1 and 2. Replace ECU Check Trans light goes out only when drive 'D' is selected Percent throttle is incorrect Refer to Code 21 troubleshooting procedure Shift selector not illuminated Light bulb burned out. Note 3. Replace light bulbs Shift selector lamp power or ground wiring faulty Check wiring from interface to panel Instrument panel circuit breaker open. Note 4. Check reason for circuit breaker being open. Reset when corrected.

Transmission stays in Neutral (will not shift), or will not make a selected shift Extremely low oil level Check transmission oil level, add if low Oil temperature too low Run engine until oil warms above -23° C (-10° F). Refer to Codes 24 and 33 troubleshooting procedures. Voltage to ECU too low Refer to Code 13 troubleshooting procedure Throttle sensor not functioning properly Refer to Code 21 troubleshooting procedure Shift selector not functioning properly Refer to Code 23 troubleshooting procedure Note 1 - Transmission will not shift. Note 3 - Other instrument panel lights operate. Note 2 - Shift system operates normally. Note 4 - Other instrument panel lights do not operate.