BMW — Final cleaning

Integral ABS Performing bleed test with BMW MoDiTeC Final inspection and function check d Warning: Self-diagnosis is not performed unless both brake levers are in their fully released positions. Prior to conclusion of the self-diagnosis, only RESIDUAL BRAKING FUNCTION is available. • Clutch • Check gear shift action. • Handbrake and foot brake • Check lights and signalling equipment: – Front and rear parking lights – Instrument lighting – Low and high headlight beams, headlight flasher – Fog lamps – Brake light (operate brake at front and rear) – Turn signals left/right – Hazard warning lights – Horn – Telltale and warning lights – Instruments • Check operation of optional extras.

• If necessary, take the motorcycle for a test ride. • Confirm pre-delivery check in Service and Tech- nical Booklet. • See “Checking motorcycle for damage” if defects are found. Perform BMW Integral ABS self-diagnosis: • Release the brake levers, if necessary. • Switch on the ignition. • With the ignition switched on, bed in the brake pads against the brake discs. ABS warning light.............................flashes at 4 Hz General warning light ........................................ ON – Self-diagnosis is in progress ABS warning light.............................flashes at 1 Hz General warning light ....................................... OFF – Self-diagnosis successfully completed.

Final cleaning Perform bleed test with BMW MoDiTeC: • Remove front and rear seats. • Connect the BMW MoDiTeC to the diagnosis connector. • Clean the motorcycle. L Note: Do not use a steam or high-pressure water jet. The high steam or water pressure could damage seals, the hydraulic system or electrical components. d Warning: When performing maintenance and repair work on BMW Integral ABS, never pump quickly or vigorous- ly. • Perform bleed test. • Perform all requisite repair work. Perform BMW Integral ABS pull-away test: • When a speed of 5 km/h (3 mph) is reached, the ABS warning light must go out. L Note:

The ABS warning light and the general warning light must both be OFF after successful self-diagnosis and the pull-away test. 00.23