Left plate assembly 1 Remove the following assemblies: Toner cartridge, media tray, and cable pod. See “Toner cartridge” on page 15 through “Cable pod” on page 17. Left side, back, right side, and top covers. See “Left side cover” on page 18 through “Top cover” on page 29. Front cover, toner cartridge door, and front guide. See “Front cover” on page 32 through “Front guide” on page 36. Fuser assembly. See “Fuser assembly” on page 42. 2 Disconnect the laser/scanner ribbon cable (at the laser/scanner end). Disconnect the laser/scanner wire harness and the ECU ribbon cable from the connector PCB. Remove the laser/scanner harness from the wire clip.
3 Remove the eight mounting screws (callout 1) and lift the left plate assembly off of the printer. 1 Figure 44. Remove the left plate assembly Q1342-90910 Internal assemblies 55