Table 3. Electrical specifications WARNING! Power requirements are based on the region where the MFP is sold. Do not convert operating voltages. This can damage the MFP and void the product warranty. The electrical and environmental specifications must be maintained to ensure the proper operation of the MFP. Consider the following points before installing the MFP: Install the MFP in a well-ventilated, dust-free area. Install the MFP on a level, flat surface that can support its size and weight. Do not install on carpet or on other soft surfaces. Make sure all four MFP feet are level. Make sure the power supply circuitry is adequate.
(See “Product specifications” on page 17.) Install the MFP where temperature and humidity are stable, with no abrupt changes (away from water sources, humidifiers, air conditioners, refrigerators, or other major appliances). (See “Product specifications” on page 17.) Install away from direct sunlight, areas that experience vibration, open flames, ammonia fumes, ultrasonic heaters, and devices that emit a magnetic field. If the MFP is placed near a window, make sure the window has a curtain or blind to block direct sunlight. Maintain enough space around the MFP for proper access and ventilation. (See “Space requirements” on page 28.) Table 4. Environmental specifications Table 5.
Noise level specifications Note Testing per International Standards Organization (ISO) 9296.
18 Chapter 1 Product information C8523-90921 Volts Frequency Amperes (amps) Watts (W) (typical) Thermal units per hour (Btu/hr) 100-127 Vac ± 10 percent 50/60 Hz ± 2 Hz Minimum recommended current capacity = 15-amp dedicated circuit printing = 1,075 W standby = 440 W PowerSave 1 = 70 W low power = 230 W off = .5 W ADF printing = 1,130 W printing = 3,670 Btu/hr standby = 1,500 Btu/hr PowerSave 1 = 240 Btu/hr low power = 785 BTu/hr off = 1.7 Btu/hr ADF printing = 3,860 220-240 Vac ± 10 percent 50/60 Hz ± 2 Hz Minimum recommended current capacity = 6.5 amp printing = 1,070 W standby = 415 W PowerSave 1 = 70 W low power = 230 W off = 1.3 W ADF printing = 1,075 W printing = 3,650 Btu/hr standby = 1,420 Btu/hr PowerSave 1 = 240 Btu/hr low power= 785 Btu/hr off = 4.5 Btu/hr ADF printing = 3,670 Operating/printing Storage/standby Temperature (MFP and print cartridge) 10 degrees to 32.5 degrees C (50 degrees to 90.5 degrees F) -20 degrees to 40 degrees C (-4 degrees to 104 degrees F) Relative humidity 20 percent to 80 percent 15 percent to 90 percent Operator position Bystander (1m) Sound power Copying at 50 ppm L 57 db(A) Pam L 60 db(A) Pam L 7.4 bels(A) WAd Idle L 40 db(A) Pam L 40 db(A) Pam L 5.7 bels(A) WAd PowerSave inaudible inaudible inaudible