Supermicro A+ Server 2021TM-BTRF/BIBXRF — Supermicro A+ Server 2021TM-BTRF/BIBXRF User Manual PDF (EN)

A+ SERVER 2021TM-BTRF/BIBXRF User's Manual Fan Confi gurations Options SC827B Hot-Swappable Default Confi guration Fan A connected to bplane, bplane connected to Node A by adapter card Fan B connected to bplane, bplane connected to Node B by adapter card Fan C connected to bplane, bplane connected to Node C by adapter card Fan D connected to bplane, bplane connected to Node D by adapter card Changing a System Fan If necessary, open the chassis while the power is running to determine which 1. fan has failed. (Never run the server for an extended period of time with the chassis cover open.) Remove the failed fan's power cord from the backplane. 2. Lift the fan housing up and out of the chassis.

3. Push the fan up from the bottom and out of the top of the housing. 4. Place the replacement fan into the vacant space in the housing while making 5. sure the arrows on the top of the fan (indicating air direction) point in the same direction as the arrows on the other fans. Confi rm that the fan is working properly before replacing the chassis cover. 6. Figure 6-5: Replacing a System Fan in the Fan Housing 6-6