7. Connection Procedure 7.3.4. Creating the Network Configuration and Transferring Create the network configuration and transfer the settings. Additional Information The node addresses 17 onwards are set for CJ1W-NC[]82 in order from the addresses that were set when EtherCAT-compatible devices other than G5-series Servo Drives are connected. 19 1 Double-click the [0000] Main Rack on the PLC IO Table Window to expand the tree. 2 Right-click 00[1500]CJ1W-NCF82 and select the Unit Setup. 3 The Network Auto Setup Dialog Box is displayed. Check the Parameter setting view message on the dialog and if there is no problem, click the OK Button.
*If the dialog box is not displayed, select Network Auto Setup from the Network Menu in the PCU Setting Window. Tree *Close any other dialog box such view as the Monitor Dialog Box if displayed. Network Auto Setup Dialog Box (PCU Setting Window)