Siemens · 12 стр.

Siemens Compensator: Руководство по эксплуатации (EN)

Оригинальное название: compensator

Читать онлайн

Похожие инструкции

Текст документа

INCLINE COMPENSATOR INCLINE COMPENSATOR Instruction Manual PL-294 September 2001

Стр. 1

Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment. These warning notices are accompanied by a clarification of the level of caution to be observed. Qualified Personnel This device/system may only be set up and operated in conjunction with this manual. Qualified personnel are only authorized to install and operate this equipment in accordance with established safety practices and standards. Warning : This product can only function properly and safely if it is correctly transported, stored, installed, set up, operated, and maintained. Note :

Always use product in accordance with specifications. MILLTRONICS®is a registered trademark of Siemens Milltronics Process Instruments Inc. Contact SMPI Technical Publications at the following address: Technical Publications Siemens Milltronics Process Instruments Inc. 1954 Technology Drive, P.O. Box 4225 Peterborough, Ontario, Canada, K9J 7B1 Email: techpubs@milltronics.com For the library of SMPI instruction manuals, visit our Web site: www.milltronics.com © Siemens Milltronics Process Instruments Inc. 2001 Copyright Siemens Milltronics Process Disclaimer of Liability Instruments Inc. 2000. All Rights Reserved This document is available in bound version and in electronic version.

We encourage users to purchase authorized bound manuals, or to view electronic versions as designed and authored by Siemens Milltronics Process Instruments Inc. Siemens Milltronics Process Instruments Inc. will not be responsible for the contents of partial or whole reproductions of either bound or electronic versions. While we have verified the contents of this manual for agreement with the instrumentation described, variations remain possible. Thus we cannot guarantee full agreement. The contents of this manual are regularly reviewed and corrections are included in subsequent editions. We welcome all suggestions for improvement. Technical data subject to change.

Стр. 2

SPECIFICATIONS Power » 115 V ± 15%, » 230 V ± 15%, » 50/60 Hz, 12 VA » voltage selection hardwired Fuse - 115 V » 1/8 amp MDL SLO-BLO - 230 V » 1/16 amp MDL SLO-BLO Input » 10.0 ± 0.1 V DC (static load cell excitation from electronic integrator) Output » 10.0 ± 0.1 V DC at 0° incline » 11.5 ± 0.1 V DC at ± 30° incline Range » 0 to ± 30° off horizontal Accuracy » will maintain integrator specification Resolution » will maintain integrator specification Temperature - operating » -40 to 60°C (-40 to 140°F) - exposure » -55 to 65°C (-67 to 149°F) Enclosure » NEMA 4 style » 292 mm H x 203 mm W x 102 mm D (11.5" H x 8" W x 4" H) Weight - open style » 735 g (1.6 lb) - NEMA 4 » 4.5 Kg (10 lb) GENERAL The Milltronics Incline Compensator provides dynamic load cell excitation to compensate for the varying vertical force component applied to the belt scale, due to varying inclination of a belt conveyor.

93/06/07 PL – 294 1

Стр. 3

The Incline Compensator receives the static load cell excitation voltage from the electronic integrator and trans- mits a dynamic load cell excitation voltage, proportional to the secant of the angle of incline. V out = V in x secant ш where: V in = static load cell excitation voltage V out = dynamic load cell excitation voltage ш = angle of incline from horizontal Vout Vin ш Although the Incline Compensator was designed to work in conjunction with Milltronics integrators and scales, it can be used with equipment not of our manufacture, providing that the required excitation voltage meets our specification. For excitation voltages other than that specified, please consult Milltronics.

INSTALLATION The Incline Compensator is mounted in a painted steel NEMA 4 enclosure, suitable for the rugged outdoor envi- ronment in which variable incline conveyors are found. The unit must be mounted to the conveyor such that the card will be standing vertically and right side up when the conveyor is level. It should be rigidly mounted on the conveyor stringer and in line with the center of the belt scale. Furthermore the unit should be mounted such that it is not subjected to excessive vibration or shock from falling material.

material flow centerline of belt scale belt scale weighing idler conveying idler conveyor belt 90 ° variable incline 0 - 30° conveyor stringer add extra support if necessary ( unit to be rigidly mounted to conveyor ) incline compensator mounted near belt scale ( left or right hand access ) PL – 294 2

Стр. 4