cisco Catalyst 9300 — Configuring Precision Time Protocol Timers

Configuring Precision Time Protocol Timers To configure the PTP timer values from default to required values, follow these steps: Before you begin Timer inputs are measured in units of log mean message interval value. To determine the value in seconds for the interval keyword, use a logarithmic scale. The following table shows examples of the value keyword that is converted to seconds with a logarithmic scale: 0 indicates 1 packet per second and -1 indicates 1 packet per 2 seconds. Procedure Configuring Precision Time Protocol (PTP) Configuring Precision Time Protocol Timers Command or Action Purpose Note You can use no ptp source command as default. Step 4 end Example:

Device(config-if)# end Returns to privileged EXEC mode. Value Entered Logarithmic Calculation Value in Seconds -1 2-1 1/2 0 20 1 Command or Action Purpose Step 1 enable Example: Device> enable Enables privileged EXEC mode. Enter your password if prompted. Step 2 configure terminal Example: Device# configure terminal Enters global configuration mode. Step 3 interface interface-id Example: Device(config)# interface gigabitethernet2/0/1 Specifies the physical port to be configured, and enters interface configuration mode. Step 4 ptp announce {interval value | timeout count} Example:

(Optional) Configures the interval between PTP announce messages on an interface or the Configuring Precision Time Protocol (PTP) 20