To identify which Grandmaster Clock identity the device is synced to in boundary mode, use show ptp parent command. show ptp parent will not display any output if the device is configured in transparent clock mode. Note The following is a sample output for show ptp parent command: Device# show ptp parent PTP PARENT PROPERTIES Parent Clock: Parent Clock Identity: 0x0:11:1:FF:FE:0:0:1 Parent Port Number: 1 Observed Parent Offset (log variance): 16640 Observed Parent Clock Phase Change Rate: N/A Grandmaster Clock: Grandmaster Clock Identity: 0x0:11:1:FF:FE:0:0:1 clock identity to which the device is synced to>> Grandmaster Clock Quality: Class: 6 Accuracy: Within 25ns Offset (log variance):
0 Priority1: 128 Priority2: 128 show platform software fed switch active ptp domain 0 To verify the local servo PTP clock synchronization to Grandmaster clock on a device configured in boundary mode with delay-request mechanism, use show platform software fed switch active ptp domain 0 command. Device# show platform software fed switch active ptp domain 0 Displaying data for domain number 0 ============================ Profile Type : DEFAULT Profile State: enabled Clock Mode : BOUNDARY CLOCK Delay mechanism: End-to-End PTP clock : 2017-6-28 5:58:59 Transport Method:
L2 Ethernet By default, local servo PTP clock will be displaying EPOCH time(1970-1-1) when the device is not synced to any PTP Grandmaster Clock. show ptp port interface-name To verify PTP port state, use show ptp port interface-name command. To verify the PTP port states on all interfaces use show ptp brief command. The following is a sample output for boundary mode configuration with delay request mechanism: Configuring Precision Time Protocol (PTP) Verifying Precision Time Protocol Configurations Configuring Precision Time Protocol (PTP) 27