5-1-2 Installation to Screen ⚫ Property Assignment This IAG reads out safety configuration information. The information is used for other IAGs. Be sure to place ReadConfiguration IAG in the first displayed screen. Assign variables to the following properties (input/output) to share the safety configuration information. ■ Screen with IAG (First Display Screen) When the screen with the configuration reading IAG is first displayed, it reads out configuration information of the controller that connected with NA. Then the information is written in the following variables.
FinishReadConfigration NA Registered ControllerName(0-15) Device Information CheckController(0-15) SafetyCPUPosition(0-15) SelectUnitNo Non-retentive Variables Area 15 Property (Input/Output) Description Data Type ControllerName Controller name of connected unit String(15) CheckController Check flag for unit connected with the safety CPU unit. Boolean(15) SafetyCPUPosition Place to where the safety CPU unit is connected. String(15) SelectUnitNo The number of selected unit. Short FinishReadConfigration Completion flag for configuration reading Boolean