omron — 2-4-1 Backup

2 Common Specifications of IAG Specifying Data Storage Location First, connect a storage device for the backup to the NA-series Programmable Terminal. • Saving to a USB Memory de- vice: Connect a USB Memory device to the USB host port • Saving to an FTP server: Connect the NA-series Programmable Terminal to the FTP server via Ether- net Use the screen on the NA-series Programmable Terminal and display ConfigureBackup. Specify the Save-in settings to set the backup storage location. • Saving to a USB Memory de- vice: Specify the full path for the save-in location • Saving to an FTP server:

Specify the FTP server connection settings (host name, mode, port, user name, and password) as well as the full path for the save-in directory Save-in location of the backup data when BackupToUSBMemory is selected Save button Save-in location of the backup data when BackupToFTPServer is selected Settings to save the difference from the last backup data when BackupToFTPServer is selected • When an FTP server is specified as the save-in location of the backup data, you can set Backup difference from the last backup to Yes to compare the actual status against the latest backup data and save only device data that has been changed since the last backup.

• Once the settings are complete, touch the Save button to save the settings. Additional Information The backup data is saved in a folder, whose name consists of Backup name and the date and time information (year, month, day, hour and minutes), in the directory specified at the Path field of Save-in . Refer to 2-5 Backup Data Structure on page 2-30 for details. 2-20 Programmable Terminals NA-series Practices Guide NJ/NX/NA-series Backup and Restore IAG (V127)