Accessories (sold separately) Fiber Amplifiers, Communications Unit and Accessories Ratings and Specifications Wire-saving Connectors Sensor I/O Connectors Dimensions (Unit: mm) Tolerance class IT16 applies to demmensions in this date sheet unless otherwise specified. Wire-saving Connectors (for Models with Wire-saving Connectors) Master Connector 94-A E3X-CN21 E3X-CN11 + 50 (Conductor cross section: 0.2 mm 2 (AWG24), Insulator diameter: 1.1 mm) Slave Connector 94-B E3X-CN22 E3X-CN12 Edge of amplifier (7) 2,000 +50 0 See note Note: E3X-CN22 : 4 dia. cable / 2 conductors / Standard length: 2 m (Conductor cross section: 0.2 mm 2 (AWG24), Insulator diameter: 1.1 mm) E3X-CN12 : 2.6 dia.
cable / 1 conductor / Standard length: 2 m (Conductor cross section: 0.2 mm 2 (AWG24), Insulator diameter: 1.1 mm) Sensor I/O Connectors (for Models with M8 Connectors) 94-C XS3F-M421-402-A XS3F-M421-405-A 4 2 2.15 M8 12.9 4 dia. 1.95 0.5 3 1 9 dia. 3.4 L 31.4 21.5 30 50 5 94-D XS3F-M422-402-A XS3F-M422-405-A 23.1 L 30 50 5 20.5 4 dia. 9 dia.
Models Cable length L (m) 2.15 3.4 XS3F-M42 -402-A 2 1.95 0.5 XS3F-M42 -405-A 5 94 Fiber Sensor Features Selection Guide Fiber Units Standard Installation Threaded Hex-shaped Cylindrical Saving Space Flat Sleeved Beam Improvements Small Spot High Power Narrow view BGS Transparent Objects Retro- reflective Limited- reflective Chemical- Immunity resistant, Oil-resistant Environmental Bending Heat- resistant Chemical- resistant, Oil-resistant Bending Applications Area Detection Liquid-level Vacuum FPD, Semi, Solar Installation Information Fiber Amplifiers, Communications Unit, and s Accessories Technical Guide and Precaution Model Index 94 Item Type Master Connector Slave Connector Models E3X-CN21 E3X-CN11 E3X-CN22 E3X-CN12 Number of conductors 4 3 2 1 Diameter of cable 4 dia.
2.6 dia. Rated current 2.5A Rated voltage 50VDC Contact resistance 20 mΩ max. (20 mVDC max., 100 mA max.) (The above figure is for connection to the Amplifier Unit and the adjacent Connector. It does not include the conductor resistance of the cable.) Number of insertions Destruction: 50 times (for connection to the Amplifier Unit and the adjacent Connector) Material Housing Polybutylene terephthalate (PBT) Contact Phosphor bronze/gold-plated nickel Weight (packed state) Approx. 55 g Approx. 25 g Item Models XS3F-M42 -40 -A Number of conductors 4 Diameter of cable 4 dia. Rated current 1A Rated voltage 125VDC Contact resistance 40 mΩ max.
(20 mVDC max., 100 mA max.) Number of insertions Destruction: 200 times 2,000 0 Edge of amplifier (7) See note Note: E3X-CN21 : 4 dia. cable / 4 conductors / Standard length: 2 m (Conductor cross section: 0.2 mm2 (AWG24), Insula E3X-CN11 : 4 dia. cable / 3 conductors / Standard length: 2 m