DAF — 3.1 Welding

TECHNICAL DATA Welding ΞΦ95 series 0 Welding on the cab - When welding on the cab, disconnect the battery terminals. - Disconnect the cab feed-through connectors and disconnect the power-supply and earth cables that are connected to the cab. - Disconnect the connectors of all electronic equipment (including sensors and actuators), if they are within a 0.5-metre radius from the point being welded or within a 0.5-metre radius from the earth terminal. 0 Welding on the superstructure - Follow the instructions for 'Welding on the chassis', together with any specific welding instructions for welding on the superstructure. Note:

During grinding, protect plastic piping, rubber components, plastic components, piston rods of hydraulic cylinders and springs (in particular parabolic springs) in order to prevent damage caused by grinding sparks. Position of feed-through connectors, earth and power supply cable The feed-through connectors (1), power supply cable (2) and earth cables are located behind the front panel in the plastic case. 1 2 3 G000240 3-2 © 200735