DAF — DAF XF95 5 until 0E621373 (EN)

5 XF 95 series Batteries DIAGNOSTICS 1  200303 1-3 SYMPTOM: SHORT BATTERY LIFE Possible cause Remedy - Wrong type of battery chosen (for example in the case of tail lifts) - Often too deeply discharged - No recharging after deep discharge (white deposits) Install Super Heavy Duty or semi-traction battery Intermediate charging with rectifier Always charge the battery after deep discharge SYMPTOM: BATTERY HOT DURING OPERATION WITH EXCESSIVE WATER CONSUMPTION Possible cause Remedy - Overcharging or charging voltage too high Check the charger (voltage regulator) SYMPTOM:

BATTERY HAS EXPLODED Possible cause Remedy - Fire or sparks during or just after charging - Short-circuiting by tools - Internal defect (loose connection) Ensure good ventilation and exercise due caution as regards fire and sparks Be careful where tools are put down Replace the battery SYMPTOM: DEFECTIVE ALTERNATOR AND/OR DIODES (RADIO AND OTHER POLARITY-SENSITIVE EQUIPMENT NOT WORKING) Possible cause Remedy - Reversed battery polarity or incorrect charging Discharge the battery, and charge in the correct direction If necessary, replace the battery SYMPTOM:

BATTERY IS INACTIVE (NO VOLTAGE) Possible cause Remedy - Internal open circuit - Battery very deeply discharged Replace the battery Charge the battery and test it; replace if necessary