5 XF 95 series Removal and installation REPAIRING WIRING 2. REMOVAL AND INSTALLATION 2.1 REMOVAL AND INSTALLATION, CONNECTORS Unlocking the connector connections The connectors can often be locked with one another or with a component. They can be divided into: A. Active locking. This means that the lock must be activated. Often a lock must be pressed with this type. B. Passive locking. Opens when the parts are pulled apart with a certain force. A 3 B E501480 Two connectors in one housing These connectors consist of two separate connectors. To remove the contacts first remove the connectors from the connector housing. Push the locking lip aside before removal.
The connector can then be slid out of the connector housing. Examples: - Connector for VIC electronic unit E501484 200303 2-1