5 XF 95 series Removal and installation REPAIRING WIRING The contacts may also be locked secondarily by the lower part of the connector. After tilting this lower part, the contacts can be removed by unlocking the primary lock using the proper ejector tool. This type of lock is used only on 2-row connectors. Examples: - MTCO connector E501497 3 A different type of secondary lock is formed by two sliding parts of the connector. The upper half (on the wire insert side) and the lower half form the extra contact lock. To unlock this secondary contact lock the upper half of the connector must be pushed away slightly in the direction of the arrows on the connector housing.
The contacts can then be removed from the connector using the proper ejector tool. E500475 After any installation of wires with contacts, the connector must be pressed into the lock again. If this is not done it will not fit into the counterpart. Application examples: - Connector, CDS electronic unit - Connector, ECAS-2/3 electronic unit - Connector for UPEC electronic unit Ejecting contacts For repair or extension of the wiring a contact may have to be replaced or added. Using special ejector tools a contact can be removed from the connector without being damaged. For the proper ejector tools, see ‘Parts Rapido’.
200303 2-3 8 8 15 15 7 6 7 6 14 13 14 13 5 5 12 12 4 3 2 4 3 2 11 10 9 11 10 9 1 1