5 TECHNICAL DATA Components XF 95 series Alternator 0 NCB1 Max. current 80 A Rated voltage 28 V NCB2 Max. current 100 A Rated voltage 28 V Micro relay Maximum cut-in current making connection between points 3 and 5: 10 A Maximum cut-out current breaking connection between points 3 and 4: 5 A +1 2 5 +3 4 E500146 3 5 2 4 1 E500147 Mini relay Maximum cut-in current making connection between points 30 and 87: 20 A Maximum cut-out current breaking connection between points 30 and 87a: 10 A 86 87a 87 85 30 87 85 86 87a 30 E500169 Handheld transmitter CDS Battery type (2x) CR1620, 3 V 1-2 200303