Chapter 2 Setup DIP switch 2 (*1) Sets whether or not to run the self-test when power is turned on. For details on the self-test, see "Self-test". (*2) In OPOS and APD4, use the DIP switch in default setting: "256x64 mode". Selecting "20 column 2 line mode" allows the display to be used as a replacement of DM-D105, 106, 205, or 206. In this mode, graphics display and functions unique to DM-D500 are unavailable. Selecting "256x64" mode makes graphics display and functions unique to DM-D500 become available. 2 (*3) In OPOS and APD4, use the DIP switch in default setting: "Display". When "Printer" is selected, data is output to the TM printer but not dis- played on the display.
When "Display" is selected, data is displayed on the display but not output from the TM printer. The device selection can be changed by using the ESC/POS command. (*4) In OPOS and APD4, use the DIP switch in default setting. (*5) Do not change the OFF setting. Changing the DIP switch settings When removing the DIP switch cover, be sure DM-D500 is turned off. Removing the cover with the power turned on may cause short circuit, which may damage the product. 1 Turn off DM-D500. 2 Remove the DIP switch cover. DSW1 DSW2 DIP switch cover 49 DSW2 No.
Function ON OFF Default setting 2-1 Y Connection Setting Enabled Disabled OFF 2-2 Self-test Execution (*1) Yes No OFF 2-3 20 column 2 line Mode Set- ting (*2) 20 column x 2 line mode 256 x 64 mode OFF 2-4 Default Device Selection Setting (*3) Printer Display OFF 2-5 Address 0 (*4) Three bits: address bit 0 to 2 are used for display number (1 to 7). (However, there is no display number when all the bits are OFF) OFF OFF OFF 2-6 Address 1 (*4) 2-7 Address 2 (*4) 2-8 Reserved for system (*5) - Fixed to OFF OFF